All your Writing needs covered

Penn foster exam 00603000 wiring electrical components

Calculate the price
of
your order:

275 words
+
Approximate price
$ 0.00

Penn foster exam 00603000 wiring electrical components Questions 1 to 20: Select the best answer to each question.  1. If you measure 20 feet between an existing box and a new box location, you should cut a piece of cable with a length of approximatelyA. 20 to 21 ft.B. 25 to 26 ft.C. 40 to 42 ft.D. 48 to 55 ft. 2. When a device is removed from an outlet box, the _______ wire must be connected in such a way that maintains continuity.A. neutralB. groundingC. hotD. grounded neutral 3. To correctly saw a lath and plaster wall, point the teeth of the sawA. away from you and cut on the pushing stroke.B. away from you and cut on the pulling stroke.C. toward you and cut on the pushing stroke.D. toward you and cut on the pulling stroke. 4. The labor performed when you extend an existing electrical system is calledA. old work.B. repair work.C. troubleshooting.D. faultfinding. 5. The basement in an existing building has concrete walls, a concrete floor, and a concrete ceiling. From this information, you know that receptacles, lamp fixtures, and switchesA. can’t be installed in this basement as there is no way to ground the circuit.B. won’t require ground-circuit protection because concrete insulates the occupants from ground.C. can be installed in the basement and circuit wiring enclosed in a surface raceway system.D. can only be installed if they’re connected with armored cable. 6. Which of the following tests must be performed on a de-energized circuit?A. Power testB. Continuity testC. Voltage testD. Current test 7. Each outside receptacle must be protected byA. a GFCI.B. its own ground rod.C. a single- or double-pole switch.D. its own circuit. 8. A circuit consists of five unequal loads connected in parallel. To measure the resistance through one specific load, you mustA. remove power from the circuit and measure the load’s resistance in its installed location.B. apply power to the circuit, disconnect the load from the circuit, and measure the load’s resistance.C. apply power to the circuit, measure the overall circuit resistance, and divide this value by five.D. remove power from the circuit, disconnect the load from the circuit, and measure the load’s resistance. 9. When new work is being performed, an outlet box must have a minimum depth ofA. 1 in.B. 11/2 in.C. 2 in.D. 21/2 in. 10. When new outlets are being added to the first floor of a two-story house with an unfinished basement, the easiest route for running cable is usuallyA. behind the wall.B. behind the baseboard.C. by way of the second floor.D. by way of the basement. 11. When an aluminum conductor is installed on a screw terminal, the screw should be tightened to a torque ofA. 8 lb-in.B. 12 lb-in.C. 15 lb-in.D. 20 lb-in. 12. A fixed electric space heater that draws a maximum current of _______ must be supplied by a cable with an ampacity of 30 A.A. 15 AB. 24 AC. 27 AD. 30 A 13. If a fixed appliance has an automatically started motor and is supplied by an individual branch circuit, the protection recommended is equal to or less thanA. twice the appliance rated current.B. 125 percent of the appliance rated current.C. the appliance rated current.D. the full service current. 14. Which of the following is a true statement about the planning stages of adding a receptacle to an existing electrical system?A. You must ensure that the existing circuit breaker will have enough capacity to handle the expected load to be applied at the new receptacle.B. It’s not acceptable to bring power from an existing box containing a light switch.C. Only nongrounding-type receptacles can be added to an existing system.D. It isn’t necessary to identify joist or stud locations prior to adding a new receptacle. 15. When installing cable behind a wall, it’s recommended to run the cable behind the baseboard rather than through the studs when theA. fish tape can’t be utilized.B. wall is plasterboard.C. wall studs are less than 16 inches apart.D. wall is plaster or lath. 16. A device box with supports is the best choice when installing aA. device box mounted in an existing drywall-covered wall.B. device box in a lath ceiling.C. device box that’s to be attached to a bar hanger.D. shallow device box in either new or existing walls. 17. A transformer that’s used with a doorbell has a fixed output ofA. 1 V.B. 10 V.C. 60 V.D. 120 V. 18. A suitable disconnecting means for a fixed appliance is aA. pigtail cord.B. light switch that interrupts the hot wire.C. circuit breaker.D. two-pole switch that interrupts the common wire. 19. The most efficient way to troubleshoot a defective electrical circuit is to start byA. replacing the components that you believe are faulty.B. having the power company evaluate the entire system’s operating efficiency.C. breaking down a multiple-circuit system into isolated circuits to be evaluated one at a time.D. bypassing the system’s main disconnect to ensure continuous power. 20. After routing cable from an existing device box through a wall and pulling the cable into a new box, your next step is toA. replace the existing receptacle with a higher-capacity device.B. apply power to the circuit.C. strip and connect the wires to the existing receptacle.D. tighten the internal cable clamps in the new box.

«VPNEW»

Unlock your academic potential with Vintage-paper.com! Place your essay order today and experience top-notch writing services that guarantee academic success. Our expert writers are ready to craft customized papers that will exceed your expectations.Don't wait, order now and elevate your grades

Order Now

Basic features

  • Free title page and bibliography
  • Unlimited revisions
  • Plagiarism-free guarantee
  • Money-back guarantee
  • 24/7 support

On-demand options

  • Writer's samples
  • Part-by-part delivery
  • Overnight delivery
  • Copies of used sources
  • Expert Proofreading

Paper format

  • 275 words per page
  • 12pt Arial/Times New Roman
  • Double line spacing
  • Any citation style (APA, MLA, CHicago/Turabian, Havard)

Guaranteed originality

We guarantee 0% plagiarism! Our orders are custom made from scratch. Our team is dedicated to providing you academic papers with zero traces of plagiarism.

Affordable prices

We know how hard it is to pay the bills while being in college, which is why our rates are extremely affordable and within your budget. You will not find any other company that provides the same quality of work for such affordable prices.

Best experts

Our writer are the crème de la crème of the essay writing industry. They are highly qualified in their field of expertise and have extensive experience when it comes to research papers, term essays or any other academic assignment that you may be given!

Calculate the price of your order

You will get a personal manager and a discount.
We'll send you the first draft for approval by at
Total price:
$0.00

Expert paper writers are just a few clicks away

Place an order in 3 easy steps. Takes less than 5 mins.